Brief Introduction
Accuracy: |
±1.0% |
Pipe size : |
1"~48" (25~1200mm) |
|
Output: |
OCT, Relay, RS485, 4-20mA ,RTD |
IP Rating: |
IP68 transducer |
|
Temperature: |
32 °F ~ 176 °F ( 0℃ ~ 80℃ ) |
Product Introduction
The D116 series ultrasonic thermal management water meter is designed for precise thermal monitoring in data centers. It uses advanced ultrasonic technology to accurately measure water flow and heat transfer. With a non-intrusive design, it clamps onto pipes without interrupting operations, making installation and maintenance simple. Its high-precision circuits and algorithms ensure reliable data collection for effective thermal management. The device provides real-time monitoring of cooling system efficiency, helping optimize energy use and prevent overheating. It is essential for maintaining the ideal thermal environment in modern data centers, supporting the continuous operation of critical IT infrastructure.
Product Applications


●Data Center Thermal Management, Research and development
●Energy management and environmental monitoring
●Liquid cooling industry,efficient cooling, temperature control, energy saving
●Hotel energy metering,Lodge cooling energy metering
●Water and wastewater management
●HVAC (Heating, Ventilation, and Air Conditioning) systems
●Process industries (chemical, pharmaceutical, food and beverage)
●Agriculture and irrigation systems
●Facilities management
●Industrial maintenance and troubleshooting
●Carbon footprint, carbon audit, carbon assessment, carbon neutrality, and carbon trading etc.
Product Parameter
1)Technical Parameters
Performance specifications |
|
Flow range |
0.03 ~ 16 ft/s ( 0.01 ~ 5.0 m/s ). |
Accuracy |
Flow accuracy: ±1% (0.5~5m/s standard condition) Energy accuracy: ±2% |
Pipe Size |
Clamp-on: 1" ~ 48" (25mm ~ 1200mm) |
Fluid |
Water. |
Pipe Material |
Carbon steel, stainless steel, PVC, Copper. |
Function specifications |
|
Output |
Analog output : 4 ~ 20mA, (max load 750Ω); Pulse output: 0 ~ 9999 Hz, OCT ( min. and max. frequency is adjustable ); Relay output: max. frequency 1Hz ( 1A@125VAC or 2A@30VDC ). |
Input Interface |
2*PT1000 interface, Three-wire system; 0~100℃(32~212℉) |
Communication interface |
RS485 MODBUS. |
Power supply |
10 ~ 36VDC/1A. |
Keypad |
16 ( 4×4 ) key with tactile action. |
Display |
20×2 lattice alphanumeric, back lit LCD. |
Temperature |
Transmitter: 14 °F to 122 °F ( –10℃ ~ 50℃ ); Transducer: 32 °F to 176 °F ( 0℃ ~ 80℃ ). |
Humidity |
Up to 99% RH, non-condensing. |
Physical specifications |
|
Transmitter |
PC/ABS, IP65. |
Transducer |
Encapsulated design, IP68. |
Transducer Cable |
Standard cable length: 30 ft (9m). |
Weight |
Transmitter: approximately 0.6kg; Transducer: approximately 0.8kg.Transducer: approximately 0.8kg |
Body Parameters
Transmitter
Transducer
PT1000 Temperature senor
Transmitter Wiring
(3) Appearance
Compatible Pipe Materials
Detectable Fluids
Installation Site Selection
Product Qualification:
For more than three decades, Gentos has been at the forefront of manufacturing top-notch, competitively priced ultrasonic flow meters, earning a reputation for excellence. We are industry leaders in innovation and eco-friendly products, striving to elevate industry standards while keeping costs reasonable.
As our product line continues to evolve, we remain committed to enhancing functionality and pushing the boundaries of quality and performance. Throughout the process of designing new products, we actively seek input from our valued customers, recognizing their invaluable contributions in shaping our success. It is through this collaborative approach that we have carved out a distinctive position in an industry that demands a seamless fusion of safety and performance.
Company environment display:
Certificate display



Deliver, Shipping, and Serving
Direct support:
Qucik response:
Fast delivery:
Shipping
Nurturing seamless customer experiences, Gentos has implemented an expedited delivery system, ensuring prompt product acquisition. Effortlessly, Gentos expedites order processing and swift product dispatch within an efficient 1 to 3 days window. Featuring an extensive selection of transportation and express delivery options, Gentos caters to the unique preferences of each customer.
FAQ
Q: Are you a trading company or a factory?
A: We have been focusing on ultrasonic flowmeters for 32 years and we are a well-known manufacturer integrating R&D and factory.
Q: What are the advantages of ultrasonic flow meters?
A: They offer non-invasive measurement, high accuracy, resistance to fluid property variations, suitability for various fluids, and low maintenance requirements.
Q: How do you install a flow meter?
A: Follow the manufacturer's installation instructions or view our youtube installation video.
Q: How to choose the right flow meter model for you?
A:Contact our technical sales with your pipe material and diameter, and we will recommend the most suitable model.
Q: Can this water meter track water usage?
A: Yes, it's designed to monitor and track water usage, detecting leaks in real time and helping manage water budgets effectively.
Hot Tags: date center thermal management water meter, China date center thermal management water meter manufacturers, suppliers, factory, BTU Meter in HVAC, ultrasonic btu meter, beer flow sensor, Industrial Ultrasonic Flow Meters, water meter with bms integration, Ball Valve
Product Parameter
1)Technical Parameters
Performance specifications |
|
Flow range |
0.03 ~ 16 ft/s ( 0.01 ~ 5.0 m/s ). |
Accuracy |
Flow accuracy: ±1% (0.5~5m/s standard condition) Energy accuracy: ±2% |
Pipe Size |
Clamp-on: 1" ~ 48" (25mm ~ 1200mm) |
Fluid |
Water. |
Pipe Material |
Carbon steel, stainless steel, PVC, Copper. |
Function specifications |
|
Output |
Analog output : 4 ~ 20mA, (max load 750Ω); Pulse output: 0 ~ 9999 Hz, OCT ( min. and max. frequency is adjustable ); Relay output: max. frequency 1Hz ( 1A@125VAC or 2A@30VDC ). |
Input Interface |
2*PT1000 interface, Three-wire system; 0~100℃(32~212℉) |
Communication interface |
RS485 MODBUS. |
Power supply |
10 ~ 36VDC/1A. |
Keypad |
16 ( 4×4 ) key with tactile action. |
Display screen |
20×2 lattice alphanumeric, back lit LCD. |
Temperature |
Transmitter: 14 °F to 122 °F ( –10℃ ~ 50℃ ); Transducer: 32 °F to 176 °F ( 0℃ ~ 80℃ ). |
Humidity |
Up to 99% RH, non-condensing. |
Physical specifications |
|
Transmitter |
PC/ABS, IP65 |
Transducer |
Encapsulated design, IP68 |
Transducer Cable |
Standard cable length: 30 ft (9m). |
Weight |
Transmitter: approximately 0.6kg; Transducer: approximately 0.8kg.Transducer: approximately 0.8kg |