Product Introduction
External Clamp Design:
The external clamp design of the GFCL streamlines installation by offering a non-invasive method that doesn't require cutting into pipes.
Permanent Coupling Paste Design
The permanent coupling paste design of the GFCL is ideal for applications where coupling agents are not needed.
High Precision of ±2%
With a precision level of ±2%, the GFCL L provides accurate and dependable flow measurements.
Compatibility with a Variety of Pipe Materials
The GFCL is designed to be compatible with a wide range of pipe materials, offering versatility and flexibility.
Brief Introduction
- Clamp on ultrasonic flow meter
- Suit for pipe diameters DN15,DN20,DN25,DN32
- Reuse for Cooper& Stainless steel &PVC &PPR
Product Applications



- Laundry,Textile industry,vegetable cleaning,Wafer Cleaning,cleaning of grinding machine,Wash Laundry Machine,Wash Laundry Stores
- Water and wastewater management
- HVAC (Heating, Ventilation, and Air Conditioning) systems
- Process industries (chemical, pharmaceutical, food and beverage)
- Energy management and environmental monitoring
- Agriculture and irrigation systems
- Research and development
- Facilities management
- Industrial maintenance and troubleshooting
- Carbon footprint, carbon audit, carbon assessment, carbon neutrality, and carbon trading etc.
Product Qualification
For more than three decades, Gentos has been at the forefront of manufacturing top-notch, competitively priced ultrasonic flow meters, earning a reputation for excellence. We are industry leaders in innovation and eco-friendly products, striving to elevate industry standards while keeping costs reasonable.
As our product line continues to evolve, we remain committed to enhancing functionality and pushing the boundaries of quality and performance. Throughout the process of designing new products, we actively seek input from our valued customers, recognizing their invaluable contributions in shaping our success. It is through this collaborative approach that we have carved out a distinctive position in an industry that demands a seamless fusion of safety and performance.
Company environment display:



Certificate display:




Deliver, Shipping, and Serving



Shipping
Nurturing seamless customer experiences, Gentos has implemented an expedited delivery system, ensuring prompt product acquisition. Effortlessly, Gentos expedites order processing and swift product dispatch within an efficient 2 to 3-day window. Featuring an extensive selection of transportation and express delivery options, Gentos caters to the unique preferences of each customer.
FAQ
Q1: What is the difference between a flow meter and a water meter?
A1: A flow meter is a device used to measure the rate of flow of a fluid (such as water, gas, or oil) in a pipeline or system. A water meter is a specific type of flow meter designed to measure the volume of water passing through a pipe
Q2: Which type of flowmeter is used for measuring water flow?
A2: The type of flow meter commonly used for measuring water flow is a water meter. Water meters are specifically designed flow meters that are calibrated to accurately measure the volume of water passing through a pipe. They are widely used by utility companies to monitor water consumption for billing purposes in residential, commercial, and industrial settings. Water meters come in various types, including mechanical (such as positive displacement and turbine meters) and electronic (such as electromagnetic and ultrasonic meters), each with its own advantages and applications.
Q3: How does water flow meter work?
A3: Water flow meters work by measuring the velocity of the water flow and then calculating the volume of water passing through the meter based on this velocity and the cross-sectional area of the pipe
Q4: How does an inductive flow meter work?
A4: Inductive flow meters work by inducing a voltage in a conductive fluid as it flows through a magnetic field. This induced voltage is then measured to determine the flow rate of the fluid passing through the meter.
Q5: How do I choose a water flow meter?
A5:When selecting a water flow meter, consider the following steps:Confirm the Properties of the Detection Fluid;Clarify the Purpose of Measurement;Confirm Product Specifications etc.
Hot Tags: gfcl flow meter for wash laundry machine, China gfcl flow meter for wash laundry machine manufacturers, suppliers, factory, Swimming Pool Flow Meter, BTU Meter for Chilled Water, Flow Meter for Marine, btu meter in petrochemical, Ball Valve, aquaculture flow meter
Product Parameter
1)Technical Parameters
|
Performance Index |
|
|
Flow velocity |
0.03m/s ~5.0m/s |
|
Accuracy |
±2%,(0.3m/s ~5m/s) |
|
Repeatability |
0.4% |
|
Medium |
Water |
|
Pipe Size |
DN15,DN20,DN25,DN32 |
|
Pipe Material |
Stainless Steel, PVC, Copper, PPR |
|
Functional Index |
|
|
Outputs |
4~20mA, |
|
Power supply |
10~36VDC/500mA |
|
Communication Interface |
RS485, Support FUJI Protocol and MODBUS Protocol |
|
Keypad |
3 touch keys |
|
Display screen |
1.54"LCD color screen, resolution 240*240 |
|
Humidity |
Relative humidity 0~99%, No condensation |
|
Temperature |
Transmitter: 14℉ to 122℉ ( -10℃ ~ 50℃ ) Transducer: 32℉ to 140℉ ( 0℃ ~ 60℃ ) |
|
IP |
IP54 |
|
Physical Characteristics |
|
|
Transmitter |
All-in-one |
|
Transducer |
Clamp on |
|
Cable |
φ5 six core cable, standard length: 2m |
2)Body Parameters

|
Model |
Nominal Inner |
W |
W1 |
L |
L1 |
H |
Ø |
|
GFCL |
DN15 |
42 |
42 |
96 |
110 |
63 |
22.5 |
|
DN20 |
42 |
59.5 |
96 |
110 |
69.5 |
29 |
|
|
DN25 |
42 |
59.5 |
96 |
110 |
76 |
35.5 |
|
|
DN32 |
42 |
64.5 |
96 |
110 |
83 |
42.5 |
|
|
DN40 |
42 |
76.5 |
96 |
110 |
95 |
54.5 |
|
|
DN50 |
42 |
85.5 |
96 |
110 |
104 |
63.5 |
3)Appearance


4)Compatible Pipe Materials

5)Detectable Fluids

6)Installation