Brief Introduction
|
Accuracy: |
±1.0% |
Pipe Size: |
1"~48" (25~1200mm) |
|
Output: |
OCT, Relay RS485, 4-20mA ,WiFi |
Medium Temperature: |
32 °F to 176 °F ( 0℃ ~ 80℃ ) |
Product Introduction
The F5 (HD) ultrasonic flowmeter is designed for precision measurement in municipal water supply systems. It utilizes advanced ultrasonic time measurement technology combined with high-reliability signal processing circuits to ensure accurate flow measurement. By employing sophisticated algorithms for sampling, calculation, and correction, the F5 can provide highly precise data even in complex conditions. The F5 is engineered for quick and easy installation, allowing for seamless integration into existing municipal water supply infrastructure. Its non-intrusive design means it can operate without direct contact with the fluid medium, thereby avoiding any disruption to the existing water flow processes.

- Municipal engineering
- Industrial water monitoring, commercial water supply metering
- Water and wastewater management
- HVAC (Heating, Ventilation, and Air Conditioning) systems
- Process industries (chemical, pharmaceutical, food and beverage)
- Energy management and environmental monitoring
- Agriculture and irrigation systems
- Research and development
- Facilities management
- Industrial maintenance and troubleshooting
- Carbon footprint, carbon audit, carbon assessment, carbon neutrality, and carbon trading etc.
Product Parameter
Technical Parameters
|
Performance specifications |
|
|
Flow range |
0.01~5.0 m/s(0.03~16 ft/s) |
|
Accuracy |
± 1.0 % of measured value (0.5m/s~5m/s) |
|
Pipe size |
Clamp-on: 25mm~800mm (1"~32") Insertion: 50mm~1200mm (2"~48") |
|
Fluid |
Water. |
|
Pipe material |
Carbon steel, stainless steel, PVC, Copper. |
|
Function specifications |
|
|
Outputs |
Analog Output: 4~20mA, with a maximum load of 750Ω Pulse Output: 0~9999Hz, OCT output (maximum and minimum frequencies are adjustable) Relay Output: Maximum frequency of 1Hz (1A @ 125VAC or 2A @ 30VDC) |
|
Communication interface |
RS485 MODBUS |
|
WiFi |
Frequency Range: 2.412~2.484GHz |
|
Transmit Power: 802.11b 16±2 dBm, 802.11n 13±2 dBm, 802.11g 14±2 dBm |
|
|
Open Environment Transmission Distance: 40 meters |
|
|
Standard TF Card |
Storage Period: Over 1000 days, Storage Interval: 1 to 3600 seconds |
|
Power supply |
10~36VDC/1A |
|
Keypad |
16 ( 4×4 ) key with tactile action. |
|
Display |
20×2 lattice alphanumeric, back lit LCD. |
|
Temperature |
Transmitter: 14 °F to 122 °F (–10℃ ~ 50℃); Transducer: 32 °F to 176 °F (0℃ ~ 80℃). |
|
Humidity |
Up to 99% RH, non-condensing. |
|
Physical specifications |
|
|
Transmitter |
PC/ABS Plastic Housing, IP Rating IP65 |
|
Transducer |
Encapsulated design, IP Rating IP68 |
|
Transducer cable |
Standard Length: 9m (30ft) |
|
Weight |
Transmitter: 0.7kg Transducer: 0.4kg |
Body Parameters

Appearance

Installation

FAQ
Q: What's the standard power supply of F5 ultrasonic flowmeter?
A: 10~36VDC/1A.
Q: How to check signal strength and quality?
A: View via Window M90 (00.0~99.9 for strength, 00~99 for Q value).
Q: What's the max cable length for clamp-on transducers?
A: Extendable up to 300 meters from standard 9m.
Q: Which window resets factory settings?
A: Press Menu 3 7, select "Reset" and confirm.
Q: What's the WiFi transmission distance in open environment?
A: Up to 40 meters (2.412~2.484GHz).
Hot Tags: municipal engineering wifi flow meter, China municipal engineering wifi flow meter manufacturers, suppliers, factory, BMS Meter, BMS Water Meter, Chilled Water BTU Meter, electrical power monitoring system, semiconductor parts cleaning, water meter with bms integration
Products Description
1)Technical Parameters
|
Performance specifications |
|
|
Flow range |
0.01~5.0 m/s(0.03~16 ft/s) |
|
Accuracy |
± 1.0 % of measured value (0.5m/s~5m/s) |
|
Pipe size |
Clamp-on: 25mm~800mm (1"~32") Insertion: 50mm~1200mm (2"~48") |
|
Fluid |
Water. |
|
Pipe material |
Carbon steel, stainless steel, PVC, Copper. |
|
Function specifications |
|
|
Outputs |
Analog Output: 4~20mA, with a maximum load of 750Ω Pulse Output: 0~9999Hz, OCT output (maximum and minimum frequencies are adjustable) Relay Output: Maximum frequency of 1Hz (1A @ 125VAC or 2A @ 30VDC) |
|
Communication interface |
RS485 MODBUS |
|
WiFi |
Frequency Range: 2.412~2.484GHz |
|
Transmit Power: 802.11b 16±2 dBm, 802.11n 13±2 dBm, 802.11g 14±2 dBm |
|
|
Open Environment Transmission Distance: 40 meters |
|
|
Standard TF Card |
Storage Period: Over 1000 days, Storage Interval: 1 to 3600 seconds |
|
Power supply |
10~36VDC/1A |
|
Keypad |
16 ( 4×4 ) key with tactile action. |
|
Display |
20×2 lattice alphanumeric, back lit LCD. |
|
Temperature |
Transmitter: 14 °F to 122 °F (–10℃ ~ 50℃); Transducer: 32 °F to 176 °F (0℃ ~ 80℃). |
|
Humidity |
Up to 99% RH, non-condensing. |
|
Physical specifications |
|
|
Transmitter |
PC/ABS Plastic Housing, IP Rating IP65 |
|
Transducer |
Encapsulated design, IP Rating IP68 |
|
Transducer cable |
Standard Length: 9m (30ft) |
|
Weight |
Transmitter: 0.7kg Transducer: 0.4kg |