The correct selection of installation pipe sections has a significant impact on testing accuracy. The selected pipe section should avoid interference and eddy currents, which have a significant impact on measurement accuracy. Generally, the selection of pipe sections should meet the following conditions:
1. Avoid installing machines in areas with strong magnetic fields and vibration interference, such as water pumps, high-power radios, and frequency converters;
2. The selection of pipes should be uniform and dense, with sections that are easy to transmit ultrasonic waves;
3. To have a sufficiently long straight pipe section, the upstream straight pipe section at the installation point must be greater than 10D (note: D=diameter), and the downstream straight pipe section must be greater than 5D;
4. The installation point should be 30D upstream from the water pump;
5. The fluid should fill the pipeline;
How to choose the correct installation location for ultrasonic flow meters