Brief Introduction

 

Accuracy:

±0.5%

Pipe Size:

1"~200" (25~5000mm)

Output:

OCT, Relay RS485, 4-20mA ,RTD

Medium Temperature:

-40℉ ~ +302℉(-40℃ ~ +150℃)

 

Product Introduction

 

The D118 is a high-performance transit-time ultrasonic flowmeter by pFlow, built with ARM/FPGA chips and low-voltage wide-pulse tech, ideal for clean liquids.

It supports not only the clamp-on sensors but also the insertion sensors enabling installation on pipes (25mm~5000mm). Sensors work at -40℃~150℃, with cables extendable to 305m.

Support 0.5% accuracy, 0.01m/s~12m/s flow range, SD card data logging (512 files), 4-20mA/OCT/relay outputs, and MODBUS/FUJI protocols.

It also functions as an energy meter (with RTD/AI temp input). Suitable for water, sewage, HVAC, and industrial processes, balancing flexibility, durability, and precision.

 

71

 

Product Applications
  • Industrial water monitoring, commercial water supply metering
  • Water and wastewater management
  • HVAC (Heating, Ventilation, and Air Conditioning) systems
  • Process industries (chemical, pharmaceutical, food and beverage)
  • Energy management and environmental monitoring
  • Agriculture and irrigation systems
  • Research and development
  • Facilities management
  • Industrial maintenance and troubleshooting
  • Carbon footprint, carbon audit, carbon assessment, carbon neutrality, and carbon trading etc.

 

Product Parameter

 

Technical Parameters

 

Performance Specifications

Flow range

±(0.03ft/s ~ 40 ft/s)

±(0.01m/s ~ 12 m/s )

Accuracy

±0.5% of measured value

Repeatability

0.15%

Linearity

±0.5%

Pipe Size

Clamp-on or Insertion : 1"~ 200" (25mm~5000mm)

Function Specifications

Outputs

Analog output: 0/4 ~ 20 mA, ( max load 750 Ω );

Pulse output: 0 ~ 9999 Hz, OCT ( min. and max. frequency is adjustable );

Relay output: max. frequency 1Hz ( 1A@125VAC or 2A@30VDC ).

Communication

Interface

RS232 & RS485.

SD card

Storage: 8GB;

Max: 512 files;

Record time interval: 1~3600s

Power Supply

90 ~ 245 VAC (48 ~ 63 Hz) Or 10~36VDC

Keypad

22 light tactile keys.

Display Screen

20 × 2 lattice alphanumeric, backlit LCD.

Temperature

Transmitter:14℉~122℉(-10℃~50℃)

Transducer:40℉~176℉(-40℃~80℃)

Transducer:32℉~302℉(0℃~150℃)

Humidity

0 to 99% RH,non-condensing

Physical Specifications

Transmitter

NEMA13 ( IP65 ).

Transducer

Encapsulated design, IP68;

Standard cable length: 9m.

Weight

Transmitter:approximately 2.15kg.

Transducer: approximately 0.9kg( standard)

 

Body Parameters

 

72

 

Appearance

 

73

 

Installation

 

74

Z installation method

 

75

V installation method

 

FAQ

 

Q: What insertion sensors can the D118 Ultrasonic Flowmeter work with?

A: It supports W211, W110, and WH insertion sensors.

Q: What's the D118's flow velocity range and accuracy?

A: Flow velocity: 0.01m/s~12m/s; accuracy: ±0.5% of measured value (0.5m/s~12m/s).

Q: How to install D118's insertion sensors without relieving pipe pressure?

A: Use ball valves-shut valves to remove sensors, no pressure relief needed.

Q: What communication protocols does the D118 support?

A: It supports RS485-FUJI Protocol and MODBUS Protocol.

Q: Can the D118 act as an energy meter?

A: Yes, with RTD module or AI temp input (4-20mA) to calculate energy.

 

Hot Tags: insertion ultrasonic flow meter, China insertion ultrasonic flow meter manufacturers, suppliers, factory

Product Parameter

 

1)Technical Parameters

 

Performance Specifications

Flow range

±(0.03ft/s ~ 40 ft/s)

±(0.01m/s ~ 12 m/s )

Accuracy

±0.5% of measured value

Repeatability

0.15%

Linearity

±0.5%

Pipe Size

Clamp-on: 1"~ 200" (25mm~5000mm)

Function Specifications

Outputs

Analog output: 0/4 ~ 20 mA, ( max load 750 Ω );

Pulse output: 0 ~ 9999 Hz, OCT ( min. and max. frequency is adjustable );

Relay output: max. frequency 1Hz ( 1A@125VAC or 2A@30VDC ).

Communication

Interface

RS232 & RS485.

SD card

Storage: 8GB;

Max: 512 files;

Record time interval: 1~3600s

Power Supply

90 ~ 245 VAC (48 ~ 63 Hz) Or 10~36VDC

Keypad

22 light tactile keys.

Display Screen

20 × 2 lattice alphanumeric, backlit LCD.

Temperature

Transmitter:14℉~122℉(-10℃~50℃)

Transducer:40℉~176℉(-40℃~80℃)

Transducer:32℉~302℉(0℃~150℃)

Humidity

0 to 99% RH,non-condensing

Physical Specifications

Transmitter

NEMA13 ( IP65 ).

Transducer

Encapsulated design, IP68;

Standard cable length: 9m.

Weight

Transmitter:approximately 2.15kg.

Transducer: approximately 0.9kg( standard)

Send Inquiry