Products
D116

D116

Water Flow Meter For Garden Hose
Non Intrusive D116 Water Flow Meter For Garden Hose use TVT Technology.
Less hardware components, low voltage broadband pulse transmission, low consumption power.
Product Introduction

 

● High Accuracy ±1.0% Measured Value

● 20×2 Alphanumeric Backlight LCD

● RS485 & 4~20mA Output

 

Product Specification

 

1)Body Parameters

Transmitter Dimensions

product-670-404

product-805-332

 

Transmitter Wiring

 

product-859-617

2)Appearance

product-900-952

3)Technical Parameters

Performance Index

Flow velocity

0.03 ~ ±16ft/s (0.01 ~ ±5m/s)

Pipe Size

1"~48" (25mm ~ 1200mm)

Measured medium

water

Pipe Material

Carbon Steel, Stainless Steel, Copper, PVC etc

Accuracy level

±1.0% of measured value

Temperature

Transmitter: IP65, ABS/PC enclosure

Ambient Temperature: 14℉ to 122℉(-10℃~50℃)

Functional Index

Communication interface

RS485 MODBUS

Power supply

10-36V DC@1Amax

Key

16 (4×4) touch keys

Display screen

20×2, alphanumeric, backlight LCD

Humidity

Up to 99% RH,non-condensing

 

Product Applications

 

Applications:Garden Irrigation,Wastewater Treatment,Liquid Hybrid Systems,

Water Softener,Fish Production Systems,Environmental Protection & Energy System.

product-508-339

Water Flow Meter For Garden Hose accurately measures fluid flow without the need for contact with the fluid, avoiding the risk of contamination or corrosion. This helps to ensure accurate irrigation volumes and improve water use efficiency.Flow data can be recorded to support data analysis and report generation. This helps the user to understand the operation of the irrigation system, optimize the irrigation strategy, improve plant growth, and can help save water and costs.

 

 

Product Qualification

 

For more than three decades, Gentos has been at the forefront of manufacturing top-notch, competitively priced ultrasonic flow meters, earning a reputation for excellence. We are industry leaders in innovation and eco-friendly products, striving to elevate industry standards while keeping costs reasonable.

As our product line continues to evolve, we remain committed to enhancing functionality and pushing the boundaries of quality and performance. Throughout the process of designing new products, we actively seek input from our valued customers, recognizing their invaluable contributions in shaping our success. It is through this collaborative approach that we have carved out a distinctive position in an industry that demands a seamless fusion of safety and performance.

 

Company environment display:

Company environment -1
Company environment -2
Company environment -3

 

Certificate display:

4001
9001
CE
CNAS
 

 

Deliver, Shipping, and Serving

Direct support001
Direct support
Quick response001
Quick response
Shipping way
Fast delivery

 

Shipping

 

Nurturing seamless customer experiences, Gentos has implemented an expedited delivery system, ensuring prompt product acquisition. Effortlessly, Gentos expedites order processing and swift product dispatch within an efficient 2 to 3-day window. Featuring an extensive selection of transportation and express delivery options, Gentos caters to the unique preferences of each customer.

 

FAQ

 

Q1: What is the purpose of a rotameter?

A1: The purpose of a rotameter is to measure the flow rate of a fluid (liquid or gas) passing through a pipe or tube. Rotameters are simple and cost-effective flow meters that rely on the principle of variable area flow measurement. The key components of a rotameter include a tapered tube through which the fluid flows, a float or ball that moves up and down based on the flow rate, and a scale to read the flow rate.

 

Q2: Why does rotameter need to be mounted vertically?

A2: Rotameters are typically designed to be mounted vertically because the float or ball inside the tube relies on the force of gravity to accurately indicate the flow rate of the fluid passing through the tube. When mounted vertically, gravity ensures that the float or ball moves freely and responds accurately to changes in flow rate.

 

Q3: What is the difference between a flowmeter and a rotameter?

A3:Flowmeters are more versatile and accurate instruments for measuring flow rates, while rotameters are simpler devices that provide a visual indication of flow rate but may have limitations in accuracy and range. The choice between a flowmeter and a rotameter depends on the specific requirements of the application and the level of accuracy needed for the flow rate measurement.

 

Q4:How does a rotameter measure flow rate?

A4:A rotameter measures flow rate by utilizing the principles of buoyancy and flow resistance to indicate the flow rate of a fluid based on the position of a float or ball within a tapered tube. It is a simple and cost-effective flow measurement instrument suitable for applications where accurate flow rate indication is sufficient.

 

Q5: How to adjust the rotameter?

A5: Adjust the measuring range of the rotameter according to your needs and fluid properties. The measuring range can be adjusted by changing the position of the float by turning the adjusting screw or adjusting the valve.

 

Hot Tags: d116, China d116 manufacturers, suppliers, factory, electrical power monitoring system, semiconductor parts cleaning, measurement of industrial waste water flow, BMS Water Meter, beer flow sensor, water flow meter IoT