Products
Leak Detection
video
Leak Detection

Leak Detection

Accuracy: ±1%
Pipe size range: 1"~48" (25~1200mm)
Measure high temperatures
D116-RTD-PT1000
Brief Introduction

 

D116 Series Ultrasonic Flowmeter is a state-of-the-art universal transit-time flowmeter designed using FPGA chip and low-voltage broadband pulse transmission.Comparing with other traditional flowmeter or ultrasonic flowmeter, it has distinctive features such as high precision, high reliability, high capability and low cost, the flowmeter features other advantages: TVT technology designed. Less hardware components, low voltage broadband pulse transmission, low consumption power.Clear, user-friendly menu selections make flowmeter simple and convenient to use.

 

Product Parameter

 

Body Parameters

Transmitter Dimension

11

12

Technical Parameters

Performance specifications

Flow range

±0.03 ~±16 ft/s (±0.01~ ±5 m/s)

Accuracy

±1.0% of measured value

Repeatability

0.3%

Pipe Size

Clamp-on: 1''~ 48″ (25mm~1200mm)

Fluid

Water

Pipe material

Carbon steel,stainless steel,PVC.

Function specifications

Outputs

Analog output: 4~20mA, Max 750 Ω. / OCT Pulse output:0~5000Hz.

Communication interface

RS485 MODBUS

Power supply

10~36VDC/1A

Keypad

16(4X 4)key with tactile action

Display

20X2 lattice alphanumeric, back lit LCD.

Transmitter

14F~122F(-10℃~50℃)

Transducer

32F~176F(0℃~80℃)

Humidity

Up to 99% RH,non-condensing

Physical specifications

Transmitter

PC/ABS,IP65.

Transducer

Encapsulated design,IP68.

Transducer cable

Standard cable length:30ft(9m).

Weight

Transmitter: approximately 0.7kg.Transducer:approximately 0.4kg

 

Product Applications

 

Applications:HVAC,Washing Machine,Tap Water,Modern Agricultural & Garden Irrigation,Water In Production Process,Industrial Circulating Water,Pure Water,Aquaculture etc.

13

14

 

The D116 ultrasonic flowmeter can monitor the flow changes of fluids in pipelines in real time. When a pipeline leaks, the fluid flow velocity and flow rate near the leak point will change, and these changes will be accurately captured and recorded by the ultrasonic flow meter. By analyzing the flow data monitored by the ultrasonic flow meter, flow abnormalities in the pipeline can be discovered in time. When the flow data fluctuates abnormally or drops suddenly, the system can initially determine that there may be a leak in the pipeline. Combined with the length, diameter and other parameters of the pipeline and the installation position of the ultrasonic flow meter, the specific location of the leakage point can be further calculated.

 

Product Qualification

 

For more than three decades, Gentos has been at the forefront of manufacturing top-notch, competitively priced ultrasonic flow meters, earning a reputation for excellence. We are industry leaders in innovation and eco-friendly products, striving to elevate industry standards while keeping costs reasonable.

As our product line continues to evolve, we remain committed to enhancing functionality and pushing the boundaries of quality and performance. Throughout the process of designing new products, we actively seek input from our valued customers, recognizing their invaluable contributions in shaping our success. It is through this collaborative approach that we have carved out a distinctive position in an industry that demands a seamless fusion of safety and performance.

 

Company environment display:

Company environment -1
Company environment -2
Company environment -3

 

Certificate display:

4001
9001
CE
CNAS
 

 

Deliver, Shipping, and Serving

Direct support001
Direct support
Quick response001
Quick response
Shipping way
Fast delivery
Shipping

 

Nurturing seamless customer experiences, Gentos has implemented an expedited delivery system, ensuring prompt product acquisition. Effortlessly, Gentos expedites order processing and swift product dispatch within an efficient 2 to 3-day window. Featuring an extensive selection of transportation and express delivery options, Gentos caters to the unique preferences of each customer.

 

FAQ

 

Q1: What are the advantages of D116?

A1: The D116 ultrasonic flowmeter adopts a non-contact measurement method, which will not cause pollution to the measured fluid or affect the normal flow of the fluid. It has high-precision measurement capabilities, can accurately capture the small flow changes of the fluid in the pipeline, and can monitor and record the flow in the pipeline in real time. The flow data provides timely and reliable data support for leak detection. Since there are no wearing parts and mechanical moving parts, the maintenance cost is low and the maintenance process is simple and convenient.

 

Q2: How to wire D116?

A2: Once the electronics enclosure has been installed, the Flowmeter wiring can be connected.Open the case, you will find the transmitter interfaces labels from left to right as follows.Power supply, Relay output, OCT Output, Upstream transducer, Downstream transducer, 4-20mA,RS485interface.Refer to the below diagram for specific connection:

16

 

Q3: What are the applications of D116 ultrasonic flowmeter in leakage systems?

A3:The advantages of D116 ultrasonic flowmeter such as high precision, strong real-time performance and non-contact measurement make it an indispensable tool in the field of leak detection. By monitoring fluid flow in real time, analyzing flow data, warning of leakage risks, and locating leak points, the D116 ultrasonic flowmeter provides a strong guarantee for the safe operation of pipelines.

 

Q4:How to install D116?

A4:Before installing the transducers, clean the pipe surface where the transducers are to be mounted. Remove any rust, scale or loose paint and make a smooth surface. Choose a section of sound conducting pipe for installing the transducers. Apply a wide band of sonic coupling compound down the center of the face of each transducer as well as on the pipe surface, ensure there are no air bubbles between the transducers and the pipe wall, and then attach the transducers to the pipe with the straps provided and tighten them securely

 

Q5: How D116 improves the efficiency of leakage systems?

A5:The D116 ultrasonic flowmeter adopts a non-contact measurement method and will not cause pollution to the measured fluid or affect the normal flow of the fluid. With high-precision measurement capabilities, it can accurately capture small flow changes in the fluid in the pipeline. The D116 ultrasonic flow meter can monitor and record the flow data in the pipeline in real time, providing timely and reliable data support for leak detection.

 

Hot Tags: leak detection, China leak detection manufacturers, suppliers, factory, Industrial Ultrasonic Flow Meters, BMS Water Meter, beer flow sensor, Ultrasonic Flow Water Meter, Flow Meter for Marine, semiconductor parts cleaning