Product Introduction
1)High Precision Measurement: The P118i handheld water flow meter utilizes advanced ultrasonic technology, providing high-precision flow measurement capabilities. Its accurate measurement results ensure the stability and accuracy of industrial processes.
2)Non-intrusive Installation: The P118i employs non-intrusive measurement technology, eliminating the need for direct contact with the fluid, thereby avoiding contamination and resistance, reducing maintenance costs, and enhancing safety.
3)High Reliability and Durability: Constructed with high-quality materials and advanced manufacturing processes, the P118i offers excellent durability and stability, capable of long-term operation in harsh industrial environments.
4)Easy Installation and Maintenance: The P118i is designed for simplicity, making installation easy, operation straightforward, and maintenance costs low. Users can quickly deploy and commission this flow meter, reducing downtime.
Product Specification
1)Body Parameters

Transmitter dimensions

Transducer dimensions

2)Appearance


3)Technical Parameters
|
Performance Index |
|
|
Flow velocity |
±0.03 ~ ±40 ft/s (±0.01~ ±12 m/s) |
|
Accuracy |
±0.5% of measured value |
|
Repeatability |
0.15%. |
|
Linearity |
±0.5%. |
|
Pipe Size |
Clamp-on:1″~ 240″ (25mm~6000mm) |
|
Functional Index |
|
|
Outputs |
Analog output: 4~20mA, Max 750 Ω., Modbus RS 485, OCT Pulse, Relay |
|
SD card |
Storage: 8GB; Max: 512 files; Interval: 1 ~ 60 seconds. |
|
Power supply |
Rechargeable Lithium Battery Power . (continuous operation of mainbattery 10 hours). |
|
Keypad |
Tactile Keys. |
|
Display screen |
3.5 inch TFT screen( 320 × 240 ), backlit LCD. |
|
Humidity |
Relative humidity 0~99%, No condensation |
|
Temperature |
Transmitter(Ambient):14℉~122℉(-10℃~50℃) Transducer-P010(Fluid): - 40℉~176℉(-40℃~80℃) Transducer-PH020(Fluid): -40℉~302℉(-40℃~150℃) |
|
Physical Characteristics |
|
|
Transmitter |
NEMA13 ( IP54 ). |
|
Transducer |
Encapsulated design, IP68; Standard cable length: 5m. |
|
Network Cable |
Transmitter:approximately1.0kg. |
Product Applications

Application:Building water system
Model name: P118i
Pipe material: PVC
Pipe size: DN200
Liquid: Water
Product Qualification
For more than three decades, Gentos has been at the forefront of manufacturing top-notch, competitively priced ultrasonic flow meters, earning a reputation for excellence. We are industry leaders in innovation and eco-friendly products, striving to elevate industry standards while keeping costs reasonable.
As our product line continues to evolve, we remain committed to enhancing functionality and pushing the boundaries of quality and performance. Throughout the process of designing new products, we actively seek input from our valued customers, recognizing their invaluable contributions in shaping our success. It is through this collaborative approach that we have carved out a distinctive position in an industry that demands a seamless fusion of safety and performance.
Company environment display:



Certificate display:




Deliver, Shipping, and Serving



Shipping
Nurturing seamless customer experiences, Gentos has implemented an expedited delivery system, ensuring prompt product acquisition. Effortlessly, Gentos expedites order processing and swift product dispatch within an efficient 2 to 3-day window. Featuring an extensive selection of transportation and express delivery options, Gentos caters to the unique preferences of each customer.
FAQ
Q1: Why flow meters are useful in the process industries?
A1: Flow meters are indispensable tools in process industries for ensuring operational efficiency, product quality, safety, regulatory compliance, resource management, and overall process optimization.
Q2: Which type of flowmeter is used for measuring water flow?
A2: The choice of flow meter for measuring water flow depends on factors such as the application, flow rate, accuracy requirements, pressure and temperature conditions, and the characteristics of the water being measured.
Q3: What flowmeter is used for high temperature?
A3:When selecting a flow meter for high-temperature applications, it is essential to consider not only the temperature range but also factors such as the flow rate, pressure, fluid characteristics, accuracy requirements, and compatibility with the process conditions
Q4:What is commonly used to measure flow?
A4:Several types of flow meters are commonly used to measure flow in various industries and applications. Some of the most commonly used flow meters include:Differential Pressure Flow Meters,Electromagnetic Flow Meters,Ultrasonic Flow Meters etc.
Q5: What are the standard conditions for a flow meter?
A5: Standard conditions for a flow meter are typically defined to ensure consistency and comparability of flow measurement data across different systems and applications. These standard conditions help in normalizing flow measurements to a common reference point.The most commonly used standard conditions for flow meters are:Temperature,Pressure,Flow Rate Units etc.
Hot Tags: handheld water flow meter, China handheld water flow meter manufacturers, suppliers, factory, Chilled Water BTU Meter, Clamp On Ultrasonic Water Flow Meter, Ultrasonic Flowmeter Clamp On Type, Ultrasonic Flow Water Meter, water flow meter IoT, ro water flow meter