Products
D116 Ultrasonic BTU Flow Meter For Buildings BMS
video
D116 Ultrasonic BTU Flow Meter For Buildings BMS

D116 Ultrasonic BTU Flow Meter For Buildings BMS

Model : D116-RTD-PT1000 (HD)
Brand : pFlow
Certification: ISO9001,ISO14001, CE

Payment & Shipping Terms
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T,Cash
Product Introduction

 

  • Precise bi-directional and highly dynamic flow measurement with the non-intrusive clamp-on technology
  • High precision at fast and slow flow rates, high temperature and zero point stability
  • Water and clean liquids; Tolerant of liquids with small amounts of air bubbles or suspended solids
  • Automatic loading of calibration data and transducer detection for a fast and easy set-up (less than 5 min), providing precise and long-term stable results
  • Clear ,user-friendly menu selections
  • Clamp on transducer and insertion transducer versions
  • Transducers available for a wide range of inner pipe diameters (25~1200mm ) and fluid temperatures (0~80℃)
  • Thermoelectric sensor is to use conversion element characteristics of electromagnetic parameters change with temperature, the temperature and temperature related parameters for testing device.The resistance change of the temperature change can be converted to known as thermal resistance sensors.Widely used in buildings BMS,industrial, medical, chemical, environmental, and other fields.

 

Brief Introduction

 

  • Wall-mounted, clamp-on BTU flow meter
  • DN25~DN1200( 1''~48'')
  • Power supply 10~36VDC
  • Transducer:IP 68

 

Product Applications

 

11001
12001

Model: D116

Pipe size: DN100

Pipe material: PVC

Medium: water

 

  • BMS,Urbanism,Architecture and civil engineering,Building Management System,BTU meter,Utility construction
  • Water and wastewater management
  • HVAC (Heating, Ventilation, and Air Conditioning) systems
  • Process industries (chemical, pharmaceutical, food and beverage)
  • Energy management and environmental monitoring
  • Agriculture and irrigation systems
  • Research and development
  • Facilities management
  • Industrial maintenance and troubleshooting
  • Carbon footprint, carbon audit, carbon assessment, carbon neutrality, and carbon trading etc.

 

Product Qualification

 

For more than three decades, Gentos has been at the forefront of manufacturing top-notch, competitively priced ultrasonic flow meters, earning a reputation for excellence. We are industry leaders in innovation and eco-friendly products, striving to elevate industry standards while keeping costs reasonable.

As our product line continues to evolve, we remain committed to enhancing functionality and pushing the boundaries of quality and performance. Throughout the process of designing new products, we actively seek input from our valued customers, recognizing their invaluable contributions in shaping our success. It is through this collaborative approach that we have carved out a distinctive position in an industry that demands a seamless fusion of safety and performance.

 

Company environment display:

Company environment -1
Company environment -2
Company environment -3

 

Certificate display:

4001
9001
CE
CNAS
 

 

Deliver, Shipping, and Serving

Direct support001
Direct support
Quick response001
Quick response
Shipping way
Fast delivery

 

Shipping

 

Nurturing seamless customer experiences, Gentos has implemented an expedited delivery system, ensuring prompt product acquisition. Effortlessly, Gentos expedites order processing and swift product dispatch within an efficient 2 to 3-day window. Featuring an extensive selection of transportation and express delivery options, Gentos caters to the unique preferences of each customer.

 

FAQ

 

Q1: How does a thermal flow meter work?

A1: A thermal flow meter operates by measuring the heat dissipation or thermal conductivity of a fluid flowing through a pipe to determine the flow rate. It typically uses a heated sensor and one or more temperature sensors to calculate the flow rate based on the difference in temperature between the heated sensor and the fluid.

 

Q2: What is a thermal meter used for?

A2: Thermal flow meters are commonly used for measuring the flow rate of gases and liquids in various industrial applications. They are particularly useful in applications where traditional flow meters may not be suitable, such as in high-temperature, high-pressure, or corrosive environments. Thermal flow meters are employed in industries such as oil and gas, chemical processing, HVAC, power generation, and water treatment for tasks such as energy monitoring, process control, and efficiency optimization.

 

Q3: What is a thermal conductivity flow meter?

A3:A thermal conductivity flow meter is a type of flow meter that operates based on the principle of thermal conductivity. It measures the flow rate of a fluid by sensing the heat transfer between a heated sensor and the fluid. As the fluid flows past the sensor, it carries away heat, and the flow rate is determined by the amount of heat transfer. Thermal conductivity flow meters are commonly used for measuring the flow of gases and liquids in various industrial applications.

 

Q4:What is the principle of heat flow meter?

A4:The principle of a heat flow meter involves measuring the heat transfer through a material or substance to determine properties such as thermal conductivity or heat flow rate. This is typically done by applying a known heat flux to one side of the material and measuring the temperature difference across it. By analyzing the heat transfer and temperature gradient, the heat flow meter can calculate the thermal properties of the material being tested. Heat flow meters are used in various applications such as building insulation testing, material characterization, and thermal performance analysis.

 

Q5: What is the thermal mass flow measurement?

A5: Thermal mass flow measurement is a technique used to measure the flow rate of a fluid (gas or liquid) based on the thermal properties of the fluid. In this method, the flow rate is determined by measuring the amount of heat required to maintain a constant temperature difference between two temperature sensors in the flow stream.

 

Hot Tags: d116 ultrasonic btu flow meter for buildings bms, China d116 ultrasonic btu flow meter for buildings bms manufacturers, suppliers, factory, inline flow control valve, BMS Meter, Data Flow Meter, measurement of industrial waste water flow, smart wifi control water valve, btu meter in petrochemical

Product Parameter

 

1)Technical Parameters

Performance Index

Flow range

0.03 ~ 16 ft/s ( 0.01 ~ 5.0 m/s )

Accuracy

Flow accuracy: ±1% (0.5~5m/s standard condition)

Energy accuracy: ±2%

Fluid

Water(chilled water,pure water,clean water,sea water,hot water,etc.)

Pipe Size

Clamp-on type: 25mm to 1,200mm (1" to 48")

Pipe Material

Stainless Steel, Carbon Steel, Copper,PVC

Functional Index

Communication Interface

RS485 MODBUS

Output

Analog output : 4 ~ 20mA, (max load 750Ω)

Pulse output: 0~9999 Hz, OCT ( min. and max. frequency is adjustable )

Relay output: max. frequency 1Hz ( 1A@125VAC or 2A@30VDC )

Input Interface

2*PT1000 interface, Three-wire system; 0~100℃(32~212℉)

Power supply

10 ~ 36VDC/1A.

Keypad

16 ( 4×4 ) key with tactile action.

Display screen

20×2 lattice alphanumeric, back lit LCD.

Humidity

Up to 99% RH, non-condensing.

Temperature

Transmitter: 14 °F to 122 °F ( –10℃ ~ 50℃ )

Transducer: 32 °F to 176 °F ( 0℃ ~ 80℃ )

IP Rating

IP65

Physical Characteristics

Transmitter

PC/ABS, IP65

Transducer

Encapsulated design, IP68

Cable

The standard length of cable: 30ft (9m)

Maximum lengthen to 1000ft(305m)

Weight

Transmitter: approximately 0.6kg

Transducer: approximately 0.8kg

 

2)Body Parameters

301

 

Transmitter

302

CP037 Transducer

303

PT1000 Temperature senor

304

Transmitter Wiring

 

3)Appearance

product-800-800

product-800-800

 

4)Compatible Pipe Materials

307

 

5)Detectable Fluids

308

 

Send Inquiry