Products
Hotel Thermal Energy Meter With Built-in Storage
video
Hotel Thermal Energy Meter With Built-in Storage

Hotel Thermal Energy Meter With Built-in Storage

Model : D118-RTD-PT1000
Brand : pFlow
Certification: ISO9001,ISO14001, CE

Payment & Shipping Terms
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T,Cash
Product Introduction

 

The D116 series ultrasonic BTU flow meter is designed for precision measurement in hotel management. It uses the ultrasonic time measurement principle, relies on high-reliability signal processing circuits, and accurately measures flow through complex algorithms such as sampling, calculation, and correction. It is designed for quick and easy installation. It can operate without direct contact with the fluid medium, effectively avoiding interference with existing production processes. It only takes a few simple steps to achieve accurate bidirectional measurement of flow and heat, and is an ideal choice for modern hotel power consumption management systems.

 

Brief Introduction

 

  • Accuracy: ±0.5%
  • Pipe size range: 1"~200" (25~5000mm)
  • Output: OCT output, Relay output, RS485, 4-20mA output,RTD input
  • Power supply: 90 ~ 245 VAC (48 ~ 63 Hz) Or 10 ~ 36 VDC
  • Encapsulated design, IP68(Transducers)

 

Product Parameter

 

1)Technical Parameters

Performance Index

Flow range

±(0.03ft/s ~ 40 ft/s) ±(0.01m/s ~ 12 m/s )

Accuracy

± 0.5% of measured value.

Repeatability

0.15%.

Fluid

Water(chilled water,pure water,clean water,sea water,hot water,etc.)

Pipe Size

1″ ~ 200″ ( 25 mm ~ 5000 mm )

Pipe Material

Carbon Steel ,Stainless Steel, Cast Iron ,Ductile Iron,Copper,

PVC,Aluminum,Asbestos,Fiber Glass--Epoxy,Other

Functional Index

Communication Interface

RS232 & RS485.

Output

Analog output : 4 ~ 20mA, (max load 750Ω)

Pulse output: 0~9999 Hz, OCT ( min. and max. frequency is adjustable )

Relay output: max. frequency 1Hz ( 1A@125VAC or 2A@30VDC )

SD Card

Max record: 512 days.

Record time interval: 1 ~ 3600 s.

Input Interface

2*PT1000 interface, Three-wire system; 0~100℃(32~212℉)

Power supply

90 ~ 245 VAC (48 ~ 6633 HHzz) Or 10 ~ 36 VDC.

Keypad

22 light tactile keys.

Display screen

20×2 lattice alphanumeric, back lit LCD.

Humidity

Up to 99% RH, non-condensing.

Temperature

Transmitter: 14 °F to 122 °F ( –10℃ ~ 50℃ )

Transducer: 32 °F to 176 °F ( 0℃ ~ 80℃ )

IP Rating

IP65

Physical Characteristics

Transmitter

PC/ABS, IP65

Transducer

Encapsulated design, IP68

Cable

The standard length of cable: 30ft (9m)

Maximum lengthen to 1000ft(305m)

Weight

Transmitter: approximately 4.7 lb ( 2.15 kg ).

Transducer: approximately 2.0 lb ( 0.9 kg ). ( standard )

 

2)Body Parameters

35

 

Transmitter

36

C011 Transducer

13

PT1000 Temperature senor

38

Transmitter Wiring

 

3)Appearance

41

42

43

 

4)Compatible Pipe Materials

45

 

5)Detectable Fluids

46

 

Product Applications

 

48

49

 

  • Energy management and environmental monitoring
  • Water and wastewater management
  • HVAC (Heating, Ventilation, and Air Conditioning) systems
  • Process industries (chemical, pharmaceutical, food and beverage)
  • Agriculture and irrigation systems
  • Research and development
  • Facilities management
  • Industrial maintenance and troubleshooting
  • Carbon footprint, carbon audit, carbon assessment, carbon neutrality, and carbon trading etc.

 

 

51

 

Product Qualification

 

For more than three decades, Gentos has been at the forefront of manufacturing top-notch, competitively priced ultrasonic flow meters, earning a reputation for excellence. We are industry leaders in innovation and eco-friendly products, striving to elevate industry standards while keeping costs reasonable.

As our product line continues to evolve, we remain committed to enhancing functionality and pushing the boundaries of quality and performance. Throughout the process of designing new products, we actively seek input from our valued customers, recognizing their invaluable contributions in shaping our success. It is through this collaborative approach that we have carved out a distinctive position in an industry that demands a seamless fusion of safety and performance.

 

Company environment display:

Company environment -1
Company environment -2
Company environment -3

 

Certificate display:

4001
9001
CE
CNAS
 

 

Deliver, Shipping, and Serving

Direct support001
Direct support
Quick response001
Quick response
Shipping way
Fast delivery

 

Shipping

 

Nurturing seamless customer experiences, Gentos has implemented an expedited delivery system, ensuring prompt product acquisition. Effortlessly, Gentos expedites order processing and swift product dispatch within an efficient 2 to 3-day window. Featuring an extensive selection of transportation and express delivery options, Gentos caters to the unique preferences of each customer.

 

FAQ

 

Q: Are you a trading company or a factory?

A: We have been focusing on ultrasonic flowmeters for 32 years and we are a well-known manufacturer integrating R&D and factory.

 

Q: What are the advantages of ultrasonic flow meters?

A: They offer non-invasive measurement, high accuracy, resistance to fluid property variations, suitability for various fluids, and low maintenance requirements.

 

Q: How do you install a flow meter?

A: Follow the manufacturer's installation instructions or view our youtube installation video.

 

Q: How to choose the right flow meter model for you?

A: Contact our technical sales with your pipe material and diameter, and we will recommend the most suitable model.

 

Q: Can this water meter track energy usage?

A: Yes, it's designed to monitor and track thermal energy usage, monitoring in real time and helping manage energy budgets effectively.

 

Hot Tags: hotel thermal energy meter with built-in storage, China hotel thermal energy meter with built-in storage manufacturers, suppliers, factory, Flow Meter for Marine, BMS Meter, BTU Meter in Chilled Water System, Heat Energy Meter, aquaculture flow meter, electronic water flow control valve

Product Parameter

 

1)Technical Parameters

Performance Index

Flow range

±(0.03ft/s ~ 40 ft/s) ±(0.01m/s ~ 12 m/s )

Accuracy

± 0.5% of measured value.

Repeatability

0.15%.

Fluid

Water(chilled water,pure water,clean water,sea water,hot water,etc.)

Pipe Size

1″ ~ 200″ ( 25 mm ~ 5000 mm )

Pipe Material

Carbon Steel ,Stainless Steel, Cast Iron ,Ductile Iron,Copper,

PVC,Aluminum,Asbestos,Fiber Glass--Epoxy,Other

Functional Index

Communication Interface

RS232 & RS485.

Output

Analog output : 4 ~ 20mA, (max load 750Ω)

Pulse output: 0~9999 Hz, OCT ( min. and max. frequency is adjustable )

Relay output: max. frequency 1Hz ( 1A@125VAC or 2A@30VDC )

SD Card

Max record: 512 days.

Record time interval: 1 ~ 3600 s.

Input Interface

2*PT1000 interface, Three-wire system; 0~100℃(32~212℉)

Power supply

90 ~ 245 VAC (48 ~ 6633 HHzz) Or 10 ~ 36 VDC.

Keypad

22 light tactile keys.

Display screen

20×2 lattice alphanumeric, back lit LCD.

Humidity

Up to 99% RH, non-condensing.

Temperature

Transmitter: 14 °F to 122 °F ( –10℃ ~ 50℃ )

Transducer: 32 °F to 176 °F ( 0℃ ~ 80℃ )

IP Rating

IP65

Physical Characteristics

Transmitter

PC/ABS, IP65

Transducer

Encapsulated design, IP68

Cable

The standard length of cable: 30ft (9m)

Maximum lengthen to 1000ft(305m)

Weight

Transmitter: approximately 4.7 lb ( 2.15 kg ).

Transducer: approximately 2.0 lb ( 0.9 kg ). ( standard )

Send Inquiry