Brief Introduction
|
Accuracy: |
Flow accuracy: ±1% , Energy accuracy: ±2% |
Pipe size : |
1"~48"(25mm~1200mm ) |
|
Flow range |
0 ~ 16 ft/s ( 0 ~ 5.0 m/s ) |
Power supply |
10 ~ 36VDC/1A. |
|
Pipe material |
Carbon Steel,Stainless Steel,Cast Iron,Ductile Iron,Copper,PVC,Aluminum,Asbestos,FiberGlass-Epoxy,Other |
||
Product Introduction
The Smart Billing Ultrasonic Energy Meter E5 is highly applicable for hospitals due to its advanced features. It can accurately measure cooling and heating energy in central air-conditioning systems, which are crucial for maintaining stable environments in medical facilities.
With WiFi connectivity to Gentos i-Cloud, real-time data monitoring and billing management are easily accessible via mobile devices or PCs.
This enables hospitals to optimize energy usage, reduce costs, and ensure efficient energy management while maintaining a comfortable and safe environment for patients and staff.
Product Applications



●Hospital
●Genetic engineering
●Carbon footprint, carbon audit, carbon assessment, carbon neutrality, and carbon trading etc.
●Water and wastewater management
●HVAC (Heating, Ventilation, and Air Conditioning) systems
●Process industries (chemical, pharmaceutical, food and beverage)
●Energy management and environmental monitoring
●Agriculture and irrigation systems
●Research and development
●Facilities management
●Industrial maintenance and troubleshooting
Product Parameter
1)Technical Parameters
|
Performance Index |
|
|
Flow range |
0 ~ 16 ft/s ( 0 ~ 5.0 m/s ) |
|
Accuracy |
Flow accuracy: ±1% of measured value., Energy accuracy: ±2% |
|
Pipe Size |
1" ~ 48" ( 25mm ~ 1200mm ) |
|
Fluid |
Water |
|
Pipe material |
Carbon Steel,Stainless Steel,Cast Iron,Ductile Iron,Copper,PVC,Aluminum,Asbestos,FiberGlass-Epoxy,Other |
|
Functional Index |
|
|
Outputs |
OCT Pulse output: 0-5000Hz. Analog output : 4 ~ 20mA, max load 750Ω. |
|
Input Interface |
2*PT1000 interface Three-wire system0~100℃(32~212℉)heat(cold) energy meter |
|
Communication interface |
RS485 MODBUS |
|
WIFI |
Frequency range: 2.412~2.484GHz |
|
Transmitting power: 802.11b 16±2 dBm 802.11n 13±2 dBm 802.11g 14±2 dBm |
|
|
Working temperature:-20~85℃ |
|
|
40m transmission distance in open environment40 |
|
|
Power supply |
10 ~ 36VDC/1A. |
|
Standard SD card |
Maximum storage period: 512 days, storage interval: 1-3600 seconds |
|
Keypad |
16 ( 4×4 ) key with tactile action. |
|
Display screen |
20×2 lattice alphanumeric, back lit LCD. |
|
Temperature |
Transmitter: 14 °F to 122 °F ( –10℃ ~ 50℃ ); Transducer: 32 °F to 176 °F ( 0℃ ~ 80℃ ). |
|
Humidity |
0~99% RH, non-condensing. |
|
Physical Characteristics |
|
|
Transmitter |
PC/ABS, IP65. |
|
Transducer |
Encapsulated design, IP68. |
|
Transducer cable |
Standard cable length:30ft(9m) |
|
Weight |
Transmitter: approximately 0.7kg; Transducer: approximately 0.4kg. |
2)Body Parameters


Transmitter

Transducer
3)Appearance


4)Compatible Pipe Materials

5)Detectable Fluids



Product Qualification:
For more than three decades, Gentos has been at the forefront of manufacturing top-notch, competitively priced ultrasonic flow meters, earning a reputation for excellence. We are industry leaders in innovation and eco-friendly products, striving to elevate industry standards while keeping costs reasonable.
As our product line continues to evolve, we remain committed to enhancing functionality and pushing the boundaries of quality and performance. Throughout the process of designing new products, we actively seek input from our valued customers, recognizing their invaluable contributions in shaping our success. It is through this collaborative approach that we have carved out a distinctive position in an industry that demands a seamless fusion of safety and performance.
Company environment display:



Certificate display:



Deliver, Shipping, and Serving
Direct support:

Qucik response:

Fast delivery:

Shipping
Nurturing seamless customer experiences, Gentos has implemented an expedited delivery system, ensuring prompt product acquisition. Effortlessly, Gentos expedites order processing and swift product dispatch within an efficient 1 to 3 days window. Featuring an extensive selection of transportation and express delivery options, Gentos caters to the unique preferences of each customer.
FAQ
Q: Are you a trading company or a factory?
A: We have been focusing on ultrasonic flowmeters for 32 years and we are a well-known manufacturer integrating R&D and factory.
Q: What are the advantages of ultrasonic flow meters?
A: They offer non-invasive measurement, high accuracy, resistance to fluid property variations, suitability for various fluids, and low maintenance requirements
Q: How do you install a flow meter?
A: Follow the manufacturer's installation instructions or view our youtube installation video.
Q: How to choose the right flow meter model for you?
A: Contact our technical sales with your pipe material and diameter, and we will recommend the most suitable model.
Q: Can this water meter track water usage?
A: Yes, it's designed to monitor and track water usage, detecting leaks in real time and helping manage water budgets effectively.
Hot Tags: smart billing ultrasonic energy meter e5 for hospital, China smart billing ultrasonic energy meter e5 for hospital manufacturers, suppliers, factory, Thermal Energy Meter, aquaculture flow meter, ro water flow meter, Flow Meter for Marine, Ultrasonic Flow Water Meter, panel mount rotameter
Product Parameter
Technical Parameters
|
Performance Index |
|
|
Flow range |
0 ~ 16 ft/s ( 0 ~ 5.0 m/s ) |
|
Accuracy |
Flow accuracy: ±1% of measured value., Energy accuracy: ±2% |
|
Pipe Size |
1" ~ 48" ( 25mm ~ 1200mm ) |
|
Fluid |
Water |
|
Pipe material |
Carbon Steel,Stainless Steel,Cast Iron,Ductile Iron,Copper,PVC,Aluminum,Asbestos,FiberGlass-Epoxy,Other |
|
Functional Index |
|
|
Outputs |
OCT Pulse output: 0-5000Hz. Analog output : 4 ~ 20mA, max load 750Ω. |
|
Input Interface |
2*PT1000 interface Three-wire system0~100℃(32~212℉)heat(cold) energy meter |
|
Communication interface |
RS485 MODBUS |
|
WIFI |
Frequency range: 2.412~2.484GHz |
|
Transmitting power: 802.11b 16±2 dBm 802.11n 13±2 dBm 802.11g 14±2 dBm |
|
|
Working temperature:-20~85℃ |
|
|
40m transmission distance in open environment40 |
|
|
Power supply |
10 ~ 36VDC/1A. |
|
Standard SD card |
Maximum storage period: 512 days, storage interval: 1-3600 seconds |
|
Keypad |
16 ( 4×4 ) key with tactile action. |
|
Display screen |
20×2 lattice alphanumeric, back lit LCD. |
|
Temperature |
Transmitter: 14 °F to 122 °F ( –10℃ ~ 50℃ ); Transducer: 32 °F to 176 °F ( 0℃ ~ 80℃ ). |
|
Humidity |
0~99% RH, non-condensing. |
|
Physical Characteristics |
|
|
Transmitter |
PC/ABS, IP65. |
|
Transducer |
Encapsulated design, IP68. |
|
Transducer cable |
Standard cable length:30ft(9m) |
|
Weight |
Transmitter: approximately 0.7kg; Transducer: approximately 0.4kg. |