Products
HVAC BTU Flow Meter
video
HVAC BTU Flow Meter

HVAC BTU Flow Meter

Model : E5E
Brand : pFlow
Certification: ISO9001,ISO14001, CE
Payment & Shipping Terms
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T,Cash

Brief Introduction

 

Accuracy:

±1.0%

Pipe size :

1"~48" (25~1200mm)

Output:

POE (Power over Ethernet)

IP Rating:

IP68 transducer

Temperature:

32 °F to 176 °F ( 0℃ ~ 80℃ )

 

Product Introduction

 

The E5E series ultrasonic BTU flow meter is designed for precision measurement in HVAC (Heating, Ventilation, and Air Conditioning) systems. It utilizes the ultrasonic time measurement principle and relies on high-reliability signal processing circuits to accurately measure flow and energy consumption. By employing sophisticated algorithms for sampling, calculation, and correction, the E5E ensures precise measurements. The E5E supports POE (Power over Ethernet) network cable power supply, which simplifies installation by providing both power and data transmission through a single cable. This feature enhances the ease of integration into modern HVAC systems. Its non-intrusive design means it can operate without direct contact with the fluid medium, effectively avoiding interference with existing processes.

 

Product Applications

 

product-1267-829

 

●Hotel energy metering,Lodge cooling energy metering

●Liquid cooling industry,efficient cooling, temperature control, energy saving

●Water and wastewater management

●HVAC (Heating, Ventilation, and Air Conditioning) systems

●Process industries (chemical, pharmaceutical, food and beverage)

●Energy management and environmental monitoring

●Agriculture and irrigation systems

●Research and development

●Facilities management

●Industrial maintenance and troubleshooting

●Carbon footprint, carbon audit, carbon assessment, carbon neutrality, and carbon trading etc.

 

Product Parameter

 

1)Technical Parameters

Performance Index

Flow range

0.03 ~ 16 ft/s ( 0.01 ~ 5.0 m/s )

Accuracy

Flow accuracy: ±1% (0.3~5m/s standard condition)

Energy accuracy: ±2%

Fluid

Water

Pipe Size

Clamp-on type: 25mm to 1,200mm (1" to 48")

Pipe Material

Stainless Steel, Carbon Steel, Copper,PVC

Functional Index

Support Protocols

HTTP,MQTT Protocol

Output

Analog output : 4 ~ 20mA, (max load 750Ω)

Pulse output: 0~9999 Hz, OCT ( min. and max. frequency is adjustable )

Relay output: max. frequency 1Hz ( 1A@125VAC or 2A@30VDC )

Input Interface

2*PT1000 interface

Three-wire system

Range: 0~100℃(32~212℉)

Power supply

POE Network cable power supply

Keypad

16 ( 4×4 ) key with tactile action.

Display screen

20×2 lattice alphanumeric, back lit LCD.

Humidity

Up to 99% RH, non-condensing.

Temperature

Transmitter: 14 °F to 122 °F ( –10℃ ~ 50℃ )

Transducer: 32 °F to 176 °F ( 0℃ ~ 80℃ )

IP Rating

IP65

Physical Characteristics

Transmitter

PC/ABS, IP65

Transducer

Encapsulated design, IP68

Cable

The standard length of cable: 30ft (9m)

Temperature sensor: Standard length: 9m(30ft)

Maximum lengthen to 1000ft(305m)

Weight

Transmitter: 0.6kg

Flow Sensor: 0.75kg

Temperature Sensor: 0.45k

 

2)Body Parameters

product-817-373

Transmitter

product-1198-411

CP037 Transducer

product-420-415

PT1000 Temperature senor

product-804-515

Transmitter Wiring

3)Appearance

product-1260-950

 

Compatible Pipe Materials

 

product-1017-230

 

Detectable Fluids

 

product-744-453

 

product-679-668

Product Qualification:

 

For more than three decades, Gentos has been at the forefront of manufacturing top-notch, competitively priced ultrasonic flow meters, earning a reputation for excellence. We are industry leaders in innovation and eco-friendly products, striving to elevate industry standards while keeping costs reasonable.

As our product line continues to evolve, we remain committed to enhancing functionality and pushing the boundaries of quality and performance. Throughout the process of designing new products, we actively seek input from our valued customers, recognizing their invaluable contributions in shaping our success. It is through this collaborative approach that we have carved out a distinctive position in an industry that demands a seamless fusion of safety and performance.

 

Company environment display:

 

product-761-690

 

product-826-700

 

product-853-642

 

Certificate display:

 

product-581-825
product-469-668
10
 

Deliver, Shipping, and Serving

 

Direct support:

product-1023-771

Qucik response:

product-1167-876

Fast delivery:

product-1024-670

 

Shipping

 

Nurturing seamless customer experiences, Gentos has implemented an expedited delivery system, ensuring prompt product acquisition. Effortlessly, Gentos expedites order processing and swift product dispatch within an efficient 1 to 3 days window. Featuring an extensive selection of transportation and express delivery options, Gentos caters to the unique preferences of each customer.

 

FAQ

 

Q: How can I ensure the accuracy of the E5E ultrasonic BTU flow meter in HVAC systems?

A: To ensure accuracy, select a proper measurement point with uniform fluid flow, input accurate pipe parameters, and use the Z method for transducer installation if the pipe diameter is over 300mm or if there is heavy scaling inside the pipe. Regularly check the signal strength and quality (Q value) displayed in Window M90 to ensure optimal performance.

Q: What should I do if the E5E flow meter shows no signal in an HVAC system?

A: If no signal is detected, verify that the transducers are correctly installed with sufficient coupling compound and that the pipe parameters are accurately entered. Ensure the pipe is full of liquid and free of air bubbles. If the issue persists, try the Z method for transducer installation or clean the pipe surface to remove any scale or rust.

Q:How do I connect the E5E flow meter to a network for data monitoring in HVAC systems?

A: The E5E flow meter supports POE (Power over Ethernet) network cable power supply. Connect the E5E to a POE switch using an RJ45 network cable. Ensure the switch is properly configured and connected to your network. You can also use the MeterTube APP to manage and monitor the device remotely.

Q: What are the power supply requirements for the E5E flow meter in HVAC applications?

A: The E5E flow meter is powered through a POE network cable, which provides both power and data transmission. Ensure the POE switch is capable of supplying the required power (typically 10~36VDC) and that the network cable is properly connected to the flow meter and the switch.

Q: How can I perform a zero calibration on the E5E flow meter in an HVAC system?

A: To perform a zero calibration, ensure the fluid in the pipe is in a static state (no flow). Press Window M42 to set the zero point. The flow meter will adjust the zero point to ensure accurate measurements at low flow rates. If the zero point is not set correctly, it can lead to measurement errors.

Hot Tags: hvac btu flow meter, China hvac btu flow meter manufacturers, suppliers, factory, Ultrasonic Flowmeter Clamp On Type, Clamp On Ultrasonic Water Flow Meter, portable ultrasonic water flow meter, aquaculture flow meter, MeterTube Platform, IoT Ball Valve

Product Parameter

 

1)Technical Parameters

Performance Index

Flow range

0.03 ~ 16 ft/s ( 0.01 ~ 5.0 m/s )

Accuracy

Flow accuracy: ±1% (0.3~5m/s standard condition)

Energy accuracy: ±2%

Fluid

Water

Pipe Size

Clamp-on type: 25mm to 1,200mm (1" to 48")

Pipe Material

Stainless Steel, Carbon Steel, Copper,PVC

Functional Index

Support Protocols

HTTP,MQTT Protocol

Output

Analog output : 4 ~ 20mA, (max load 750Ω)

Pulse output: 0~9999 Hz, OCT ( min. and max. frequency is adjustable )

Relay output: max. frequency 1Hz ( 1A@125VAC or 2A@30VDC )

Input Interface

2*PT1000 interface

Three-wire system

Range: 0~100℃(32~212℉)

Power supply

POE Network cable power supply

Keypad

16 ( 4×4 ) key with tactile action.

Display screen

20×2 lattice alphanumeric, back lit LCD.

Humidity

Up to 99% RH, non-condensing.

Temperature

Transmitter: 14 °F to 122 °F ( –10℃ ~ 50℃ )

Transducer: 32 °F to 176 °F ( 0℃ ~ 80℃ )

IP Rating

IP65

Physical Characteristics

Transmitter

PC/ABS, IP65

Transducer

Encapsulated design, IP68

Cable

The standard length of cable: 30ft (9m)

Temperature sensor: Standard length: 9m(30ft)

Maximum lengthen to 1000ft(305m)

Weight

Transmitter: 0.6kg

Flow Sensor: 0.75kg

Temperature Sensor: 0.45k

Performance Index

Flow range

0.03 ~ 16 ft/s ( 0.01 ~ 5.0 m/s )

Accuracy

Flow accuracy: ±1% (0.5~5m/s standard condition)

Energy accuracy: ±2%

Fluid

Water(chilled water,pure water,clean water,sea water,hot water,etc.)

Pipe Size

Clamp-on type: 25mm to 1,200mm (1" to 48")

Pipe Material

Stainless Steel, Carbon Steel, Copper,PVC

Functional Index

Communication Interface

RS485 MODBUS

Output

Analog output : 4 ~ 20mA, (max load 750Ω)

Pulse output: 0~9999 Hz, OCT ( min. and max. frequency is adjustable )

Relay output: max. frequency 1Hz ( 1A@125VAC or 2A@30VDC )

Input Interface

2*PT1000 interface, Three-wire system; 0~100℃(32~212℉)

Power supply

10 ~ 36VDC/1A.

Keypad

16 ( 4×4 ) key with tactile action.

Display screen

20×2 lattice alphanumeric, back lit LCD.

Humidity

Up to 99% RH, non-condensing.

Temperature

Transmitter: 14 °F to 122 °F ( –10℃ ~ 50℃ )

Transducer: 32 °F to 176 °F ( 0℃ ~ 80℃ )

IP Rating

IP65

Physical Characteristics

Transmitter

PC/ABS, IP65

Transducer

Encapsulated design, IP68

Cable

The standard length of cable: 30ft (9m)

Maximum lengthen to 1000ft(305m)

Weight

Transmitter: approximately 0.6kg