Brief Introduction
|
Accuracy: |
Flow: ± 1.0 % Energy: ± 2.0 % |
Pipe Size: |
Clamp-on: 25mm~800mm (1"~32") Insertion: 50mm~1200mm (2"~48") |
|
Flow Rage: |
0.01 m/s~5.0 m/s (0.03 ft/s~16ft/s) |
Communication Interface: |
RS485 MODBUS |
Product Introduction
The E5 Ultrasonic Energy Meter delivers accurate, real-time flow and energy data, seamlessly integrating into Building Automation Systems for smarter HVAC control. Ideal for energy efficiency and system optimization in commercial and industrial buildings.
- Cut energy waste
- Low power consumption
- Accurate Flow & Energy Monitoring

- Building Automation System
- HVAC (Heating, Ventilation, and Air Conditioning) systems
- Process industries (chemical, pharmaceutical, food and beverage)
- Energy management and environmental monitoring
- Agriculture and irrigation systems
- Research and development
- Facilities management
- Industrial maintenance and troubleshooting
- Carbon footprint, carbon audit, carbon assessment, carbon neutrality, and carbon trading etc.
Product Parameter
Technical Parameters
|
Performance specifications |
|
|
Flow range |
0.01 m/s~5.0 m/s (0.03 ft/s~16ft/s) |
|
Accuracy |
Flow: ± 1.0 % of measured value (0.5m/s~5m/s) Energy: ± 2.0 % |
|
Pipe Size |
Clamp-on: 25mm~800mm (1"~32") Insertion: 50mm~1200mm (2"~48") |
|
Fluid |
Water |
|
Pipe material |
Carbon steel, stainless steel, PVC |
|
Function specifications |
|
|
Outputs |
Analog Output: 4~20mA, with a maximum load of 750Ω Pulse Output: 0~9999Hz, OCT output (maximum and minimum frequencies are adjustable) Relay Output: Maximum frequency of 1Hz (1A @ 125VAC or 2A @ 30VDC) |
|
Input Interface |
2*PT1000 interfaces, 3-wire system 0~100℃(32~212℉) |
|
Communication interface |
RS485 MODBUS |
|
Power supply |
10~36VDC/1A |
|
WiFi |
Frequency Range: 2.412~2.484GHz |
|
Transmit Power: 802.11b 16±2 dBm, 802.11n 13±2 dBm, 802.11g 14±2 dBm |
|
|
Open Environment Transmission Distance: 40 meters |
|
|
Standard TF Card |
Storage Period: Over 1000 days, Storage Interval: 1 to 3600 seconds |
|
Keypad |
16 ( 4×4 ) key with tactile action |
|
Display |
20×2 lattice alphanumeric, back lit LCD |
|
Temperature |
Transmitter: 14 °F to 122 °F (–10℃ ~ 50℃) Transducer: 32 °F to 176 °F (0℃ ~ 80℃) |
|
Humidity |
Up to 99% RH, non-condensing. |
|
Physical specifications |
|
|
Transmitter |
PC/ABS Plastic Housing, IP Rating IP65 |
|
Transducer |
Encapsulated design, IP Rating IP68 |
|
Transducer cable |
Standard Length: 9m (30ft) |
|
Weight |
Transmitter: 0.7kg Transducer: 0.4kg |
Appearance

Installation

FAQ
Q: Are you a trading company or a factory?
A: We have been focusing on ultrasonic flowmeters for 32 years and we are a well-known manufacturer integrating R&D and factory.
Q: What are the advantages of ultrasonic flow meters?
A: They offer non-invasive measurement, high accuracy, resistance to fluid property variations, suitability for various fluids, and low maintenance requirements.
Q: How do you install a flow meter?
A: Follow the manufacturer's installation instructions or view our youtube installation video.
Q: How to choose the right flow meter model for you?
A: Contact our technical sales with your pipe material and diameter, and we will recommend the most suitable model.
Q: Can this water meter track water usage?
A: Yes, it's designed to monitor and track water usage, detecting leaks in real time and helping manage water budgets effectively.
Hot Tags: ultrasonic energy meter for building automation, China ultrasonic energy meter for building automation manufacturers, suppliers, factory, beer flow sensor, BMS Water Meter, electrical power monitoring system, Industrial Ultrasonic Flow Meters, measurement of industrial waste water flow, semiconductor parts cleaning
Products Description
1)Technical Parameters
|
Performance specifications |
|
|
Flow range |
0.01 m/s~5.0 m/s(0.03 ft/s~16ft/s) |
|
Accuracy |
Flow: ± 1.0 % of measured value (0.5m/s~5m/s) Energy: ± 2.0 % |
|
Pipe Size |
Clamp-on: 25mm~800mm (1"~32") Insertion: 50mm~1200mm (2"~48") |
|
Fluid |
Water |
|
Pipe material |
Carbon steel, stainless steel, PVC |
|
Function specifications |
|
|
Outputs |
Analog Output: 4~20mA, with a maximum load of 750Ω Pulse Output: 0~9999Hz, OCT output (maximum and minimum frequencies are adjustable) Relay Output: Maximum frequency of 1Hz (1A @ 125VAC or 2A @ 30VDC) |
|
Input Interface |
2*PT1000 interfaces, 3-wire system 0~100℃(32~212℉) |
|
Communication interface |
RS485 MODBUS |
|
Power supply |
10~36VDC/1A |
|
WiFi |
Frequency Range: 2.412~2.484GHz |
|
Transmit Power: 802.11b 16±2 dBm, 802.11n 13±2 dBm, 802.11g 14±2 dBm |
|
|
Open Environment Transmission Distance: 40 meters |
|
|
Standard TF Card |
Storage Period: Over 1000 days, Storage Interval: 1 to 3600 seconds |
|
Keypad |
16 ( 4×4 ) key with tactile action |
|
Display |
20×2 lattice alphanumeric, back lit LCD |
|
Temperature |
Transmitter: 14 °F to 122 °F (–10℃ ~ 50℃) Transducer: 32 °F to 176 °F (0℃ ~ 80℃) |
|
Humidity |
Up to 99% RH, non-condensing. |
|
Physical specifications |
|
|
Transmitter |
PC/ABS Plastic Housing, IP Rating IP65 |
|
Transducer |
Encapsulated design, IP Rating IP68 |
|
Transducer cable |
Standard Length: 9m (30ft) |
|
Weight |
Transmitter: 0.7kg Transducer: 0.4kg |