Ultrasonic Flowmeter For Liquid Cooling System
video
Ultrasonic Flowmeter For Liquid Cooling System

Ultrasonic Flowmeter For Liquid Cooling System

Model : GFR
Brand : pFlow
Certification: ISO9001,ISO14001, CE

Payment & Shipping Terms
Minimum Order Quantity: 1
Delivery Time: 3-5 working days
Payment Terms: T/T,Cash

Brief Introduction

 

Accuracy:

±2%,(1.0~16ft/s)

Pipe Size:

DN15, DN20, DN25, DN32

Power Supply:

10~36VDC/500mA

Key :

3 touch keys

 

Product Introduction

 

GFR ultrasonic flow meters can be quickly installed on DN15-32 stainless steel, copper, PVC or PPR pipes within 1 minute. Their transit time sensor provides ±2% accuracy in the range of 0.03-5 m/s and can be installed on pipes of 18-63 mm without interrupting flow-making them ideal for liquid cooling systems.

  • Easy to install,without break pipe
  • Easily clip on
  • LCD color display

 

111

 

Product Applications
  • Liquid Cooling system
  • Process industries (chemical, pharmaceutical, food and beverage)
  • Energy management and environmental monitoring
  • Agriculture and irrigation systems
  • Research and development
  • Commercial
  • Industrial maintenance and troubleshooting
  • Carbon footprint, carbon audit, carbon assessment, carbon neutrality, and carbon trading etc.

 

Product Parameter

 

Technical Parameters

 

Performance specifications

Flow velocity

0.03 m/s ~ 5.0 m/s

Accuracy

± 2.0 % of measured value

Repeatability

0.4%

Pipe Size

DN15, DN20, DN25, DN32

Medium

Water.

Pipe Material

Stainless Steel, PVC, Copper, PPR

Functional Index

Communication interface

RS485, FUJI or MODBUS Protocol

LoRa Communication

Maximum Transmit Power: 22dBm

Temperature: -40℃~85℃

LoRaWAN communication protocol is available

LoRa Frequency selection

EU868 Frequency: 863000000~865400000, unit Hz

US915 Frequency: 902300000~914900000, unit Hz

CN779 Frequency: 780100000~786500000, unit Hz

EU433 Frequency: 433775000~434665000, unit Hz

AU915 Frequency: 915200000~927800000, unit Hz

CN470 Frequency: 470300000~489300000, unit Hz

AS923(HK) Frequency: 920000000~925000000, unit Hz

Power Supply

10~36VDC/500mA

Keypad

3 touch keys

Display Screen

1.54"LCD color screen, resolution 240*240

Temperature

Transmitter: 14 °F to 122 °F ( –10℃ ~ 50℃ );

Transducer: 32 °F to 140 °F ( 0℃ ~ 60℃ ).

Humidity

Up to 99% RH, non-condensing.

IP

IP54

Physical Characteristics

Transmitter

All-in-one

Transducer

Clamp on

Cable

φ5 six core cable, standard length: 2m

 

Body Parameters

 

113

114

 

Appearance

 

115

 

Installation

 

116

 

FAQ

 

Q: Are you a trading company or a factory?

A: We have been focusing on ultrasonic flowmeters for 32 years and we are a well-known manufacturer integrating R&D and factory.

Q: Does installing the GFR require shutting down the liquid-cooling loop or cutting pipes?

A: No-its clamp-on transducers mount in minutes without breaking the pipe or stopping flow, so servers stay online.

Q: Which pipe materials and sizes can the GFR handle?

A: It fits DN15–DN50 stainless-steel, copper, PVC or PPR pipes; Class-A/B clamps cover OD 18–64 mm with no hardware changes.

Q: How accurate is the GFR in small cooling lines?

A: Factory calibration gives ±2 % of reading from 0.3–5 m/s (0.03 m/s minimum) and repeatability of 0.4 %.

Q: How is the meter powered and how can I access its data?

A: 10–36 VDC supply feeds the unit; data leaves via RS485-Modbus or LoRaWAN (22 dBm, region-selectable) for direct BMS or cloud integration.

 

Hot Tags: ultrasonic flowmeter for liquid cooling system, China ultrasonic flowmeter for liquid cooling system manufacturers, suppliers, factory, BMS Meter, BMS Water Meter, electrical power monitoring system, measurement of industrial waste water flow, semiconductor parts cleaning, Waste Water Meter

Products Description

 

1)Technical Parameters

Performance specifications

Flow velocity

0.03 m/s ~ 5.0 m/s

Accuracy

± 2.0 % of measured value

Repeatability

0.4%

Pipe Size

DN15, DN20, DN25, DN32

Medium

Water.

Pipe Material

Stainless Steel, PVC, Copper, PPR

Functional Index

Communication interface

RS485, FUJI or MODBUS Protocol

LoRa Communication

Maximum Transmit Power: 22dBm

Temperature: -40℃~85℃

LoRaWAN communication protocol is available

LoRa Frequency selection

EU868 Frequency: 863000000~865400000, unit Hz

US915 Frequency: 902300000~914900000, unit Hz

CN779 Frequency: 780100000~786500000, unit Hz

EU433 Frequency: 433775000~434665000, unit Hz

AU915 Frequency: 915200000~927800000, unit Hz

CN470 Frequency: 470300000~489300000, unit Hz

AS923(HK) Frequency: 920000000~925000000, unit Hz

Power Supply

10~36VDC/500mA

Keypad

3 touch keys

Display Screen

1.54"LCD color screen, resolution 240*240

Temperature

Transmitter: 14 °F to 122 °F ( –10℃ ~ 50℃ );

Transducer: 32 °F to 140 °F ( 0℃ ~ 60℃ ).

Humidity

Up to 99% RH, non-condensing.

IP

IP54

Physical Characteristics

Transmitter

All-in-one

Transducer

Clamp on

Cable

φ5 six core cable, standard length: 2m

Send Inquiry